Fixed heptafluoropropane gas detector with radio signal transmission

Fixed Heptafluoropropane Gas Detector with Radio Signal TransmissionBrief introduct of Gas detector:Fixed ammonia detector can also have a field detection concentration display, signal transmission, led lights and relay alarm function.Volkswagen series shows the fixed ammonia detector works is the site of the detection of ammoni

Featured Products

Fixed Heptafluoropropane Gas Detector with Radio Signal Transmission


Brief introduct of Gas detector:
Fixed ammonia detector can also have a field detection concentration display, signal transmission, led lights and relay alarm function.Volkswagen series shows the fixed ammonia detector works is the site of the detection of ammonia gas concentration, converted to the corresponding standard signals (such as voltage signals (such as 0-5 / 10V), current signals (such as 4-20mA) , Standard digital signals (such as bus RS-485, RS232), frequency signal, Hart protocol signal, and then send the signal to the PLC, DCS, alarm control host and other host computer for unified display, management and control. Gas detector with a relay inside (switch signal), you can control the fan, sound and light alarm, solenoid valve and other equipment.
Features of Gas detector:
1.Volkswagen series Wall-mounted ammonia detector can be connected to the Ampel server to achieve mobile phone and computer remote monitoring, alarm reminders and alarm settings, etc.
2.Ultra-high-definition color display. Long distance visual, visual distance of 10 meters (5.0 vision).
3.Standard signal output range; Volkswagen series with fixed ammonia detector display cable output signal has a variety of options
4.Chinese and English lanuage switch free.
5.Black box function: operation, alarm records, over-temperature use records, over-range use records;
6.Reminders and alarm function is complete: sensor expiration reminder function, ultra-concentration alarm function, over-temperature alarm function,
Fault alarm function, instrument calibration reminder function;
7.Flameproof design, intrinsically safe design, RoHS design
8.Zero automatic correction: for some environmental applications, the instrument can achieve zero automatic correction function.
9.Dual operation mode: key operation + remote control operation
Fixed Heptafluoropropane Gas Detector with Radio Signal TransmissionFixed Heptafluoropropane Gas Detector with Radio Signal Transmission
Fixed Heptafluoropropane Gas Detector with Radio Signal TransmissionFixed Heptafluoropropane Gas Detector with Radio Signal Transmission

 
NameAmmonia gas detector
Test gasAmmonia gas
Measuring rangeDepends on real application
Display unit ppm,mg/m3, ppb,pphm,%VOL,%LEL
ResolutionDepends on measuring range you choosed
Accuracy≤±3%FS
Repeatability≤±1%
Response time≤3(T1);≤15(T90)
Recovery Time≤20(T90-T10)
Display320*240 HD color screen,2.0 inch
Visual distance≥10 m (5.0 eyesight)
System languageEnglish and Chinese
Operation modeInfrared remote control, key (open cover), remote network (such as mobile phone APP or PC software)
Detection modeDiffuse
Installation modeWall-mounted (wall-mounted), rod-mounted (cross bar or pole)
Shell materialBody: alloy (anti-corrosion anti-oxidation surface treatment) or stainless steel. Probe: anti-corrosion alloy or 316L stainless steel
Explosion-proof markDouble explosion standard Exd CT6 and Ex Td A21
Protection rateIP66
Work temperature-40 ºC ~ 70 ºC (general catalytic combustion principle sensor)
-40 ºC ~ 270 ºC (special catalytic combustion)
-40 ºC ~ 50 ºC (electrochemical)
-20 ºC ~ 50 ºC (pid principle sensor)
-20 ºC ~ 50 ºC (infrared / fluorescence gas sensor)
-40 ºC ~ 70 ºC (thermal conductivity principle sensor)
-40 ºC ~ 420 ºC (zirconia principle oxygen sensor)
Work humidity10% ~ 95% RH, no condensation (humidity> 90% RH, condensation optional filter)
Work pressure0.08 ~ 0.6MPa (thermal conductivity principle sensor)
0.02 ~ 0.36MPa (zirconia principle oxygen sensor)
86 ~ 106KPa (other)
Temperature measuring range-40 ºC ~ +120 ºC Accuracy ± 1 ºC (with temperature compensation function)
Output signalTwo-wire system 4-20mA
Two-wire Hart
Three-wire system 4-20mA + 1 relay (switch, optional function)
Voltage 0 ~ 5 / 10V + 1 relay (switch, optional function)
RS-485 + 1 relay (switch, optional)
RS-422 + 1 relay (switch, optional)
Three-wire current 4 ~ 20mA + RS-485 + 1 relay (switch, optional function)
Voltage 0 ~ 5 / 10V + RS-485 + 1 relay (switch, optional function)
Frequency signal (adjustable) + 1 relay (switch, optional function)
Three-wire Hart + 1 relay (switch, optional)
CAN bus + 1 relay (switch, optional)
Note: Relay (switch) Specifications: Output 2A @ 30VDC or 0.6A@125VAC
Power consumptionElectrochemical sensor: P ≤ 0.9W
Ordinary catalytic sensor: P ≤ 2.3W
Low power catalytic sensor: P ≤ 1.2W
Thermal conductivity sensor: P ≤ 1.2W
Infrared sensor: P ≤ 1.4W
PID sensor: P ≤ 1.2W
Alarm Panel LED alarm, display character flashing and information reminder, relay output
Control outputExternal fans, valves, sound and light alarm
ProtectionIntermittent detection, sensor automatic protection function (optional)
Work life2 years (sensor), 5 years (instrument)
Power supply12-35VDC, typical power supply 24VDC
SizeOverall size: 205 * 184 * 93mm (L * W * H) - Volkswagen series Basic type
Size: Inner thread M20 * 1.5 (G1 / 2 internal thread, G3 / 4 internal thread, 1 / 2NPT internal thread, NPT3 / 4NPT internal thread is optional);
Weight≥1.65kg
CertificateCertification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification, certification
StandardGB 15322.1-2003, GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, 
GB 12476.1-2013, GB 12476.4-2010,GB 12476.5-2 013, 
JJF 1363-2012, JJF 1368-2012, JJF 1421-2013, JJF 1364-2012
 

FAQ     

1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

 

Pre-sale service

· 24hours online to ensure quick response to customers' inquiry or online message;

· Guide customers to choose the best suitable machine model;

· Offer detailed specification and competitive prices;

Contract execution

· Machine production will be arranged strictly according to the contract;

· Machine photos will be sent to you for inspection during production;

· Send customs clearance documents by DHL;

· Update latest news after delivery and prepare customs clearance;

After-sale service

· 12 months warranty except for wear parts;

· Broken spare parts (except for wear parts) will be sent for free due to quality problems;

· In time response to customers technical problems;

· New products update for customers' reference


Our Company:
Since 2008, We have become a professional laboratory instrument manufacturer.
Since the establishment of the International Department in 2010, the products are exported to Europe, America and Asia and Africa!
Whether it is technology, factory area, multi-language sales. We are all professional!
Fixed Heptafluoropropane Gas Detector with Radio Signal Transmission

Factory Show:

Fixed Heptafluoropropane Gas Detector with Radio Signal Transmission
Certification:

Our products have international certifications such as SGS, CE, ISO!
Fixed Heptafluoropropane Gas Detector with Radio Signal Transmission
Warranty And After-sale Service

♥♥We Supply 1 Year Warranty , And Lifelong Free Technical Guiding And Training♥♥
Fixed Heptafluoropropane Gas Detector with Radio Signal Transmission

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours